Heating area: 1440-2880m²

Features
  • Electrical leakage protection;
  • High/low pressure protection;
  • Alarm function;
  • Short circuit protection;
  • Antifreeze protection;
  • Overheat protection;
Send
Parameter

BYD-C180SLC1-F for touch screen type air cooled model
BYD-C240SLC1-S for touch screen type water cooled model
BYD-C240SLC1-F for touch screen type air cooled model

Model Unit
BYD-C180SLC1-F
BYD-C240SLC1-S
BYD-C240SLC1-F
Rated power kW 180 240 240
Rated current A 270 360 540
Voltage/Frequency V/Hz 380/50-60 380/50-60 380/50-60
Cross section area of power cable mm² ≥150 ≥185 ≥185
Heating efficiency % ≥98 ≥98 ≥98
Max. pressure of heating Mpa 0.2 0.2 0.2
Min. flow of pump L/min 216 316 336
Expansion tank volume L 180 240 240
Max. heating temperature 90 90 90
Temperature of low temperature protection 5 5 5
65ºC hot water output L/min 58.5 78 78
Dimensions mm 1910*1315*1000 1910*1315*1000 1910*1720*1000
Inlet/outlet connection DN 80 80 100
Heating area 1440-2160 1920-2880 1920-2880
Heat dissipation of enclosure % ≤2 ≤2 ≤2
Max. volume of heating L 3300 4400 4400
Heating space 6300-8550 8300-11480 8300-11480
Electric meter A 3-phase power meter 1.5-1.6A, metering transformer needs to be installed rationally by professional personnel
Protection grade IP 33 33 33
Dimensioning
Features

Energy Saving
When the indoor temperature exceeds the pre-set value, the central heating boiler will be automatically turned off, thus efficiently saving more than 30% energy. And it can save energy by 20% in comparison with traditional boilers that use resistance heating method.

Constant Temperature and Comfortable Space
Water temperature can be controlled within a range of 5~90ºC, and the precision of temperature control can reach ±1ºC, providing a comfortable atmosphere for your space. Unlike air conditioning equipment, induction heating does not create an ideal environment for bacteria to grow.

No Noise
In contrast to central heating boilers using air cooling method, water cooled heating boilers are more quiet and unobtrusive.

Safe Operation
Utilizing induction heating achieves separation of electricity and water, providing a safer operation. Besides, multiple protection functions such as antifreeze protection, electricity leakage protection, short circuit protection, phase loss protection, overheating protection, overcurrent protection, overvoltage protection, undervoltage protection, self-inspection protection are equipped. Safe usage is guaranteed for 10 years.

Intelligent Control
Our induction central heating boilers can be WIFI remotely controlled by smart phones.

Easy to Maintain
Induction heating do not constitute the condition of fouling, eliminating the need for fouling removing treatment.

Installation
  • Direct Installed Heating Mode
  • Installation Method of Fan Coil Unit
  • Idirect Heat Sink Installation
  • Hot Water Storage Tank Installation
FAQ

Please Contact Our Customer Service before Make a Purchase

  • About Choosing Appropriate Power

    Choosing a suitable boiler based on your actual heating area
    For low-energy buildings, 60~80W/m² boilers are suitable;
    For general buildings, 80~100W/m² boilers are suitable;
    For villas and bungalows, 100~150W/m² boilers are suitable;
    For those buildings where sealing performance is not well and room height is greater than 2.7m or people frequently enter, the building heat load is correspondingly increased and the power of central heating boiler should be higher.

  • About Installation Conditions

    What are installation conditions
    Take a 15kW induction central heating boiler as an example:
    The cross section are of main power cable should not be less than 6mm3, main switch 32~45A, voltage 380V/50, minimum water flow of pump is 25L/min, the water pump needs to be selected according to building height.

  • About Accessories

    What accessories are required
    Since every installation site of customer is different, so that various accessories are required. We only provide central heating boilers, other accessories such as pump valve, piping and union connectors need to be purchased by customers.

  • About Connections For Heating

    What are applicable connections for heating
    BIYDA’s induction central heating boilers can be flexibly connected to floor heating system, radiator, hot water storage tank, fan coil unit (FCU), etc.

  • About Installation Service

    Our products can be installed by our authorized local dealers. We also accept advance reservation, and we designate engineers to offer installation service and technical guidance on site.

  • About Logistics

    Shipping time and logistic distribution
    We promise to ship our ready-to-ship products within 24 hours, and ship our made-to-order products within 7-10 days. And the logistics service is based on customers’ requirements.

  • About Service Life

    How long is this product’s service life
    BIYDA’s induction central heating boiler adopts high-frequency induction coil and industrial grade inverter, all key parts are made of imported high grade materials, its service life can reach 15 years or more.

Case Studies

Project: Water heating solution for Xinjiang Urumqi Yongli Water World Hotel
Clients’ needs: Induction heating area of 13,500 square meters
Products used: 4 Biyuanda 240KW variable frequency induction heating furnace
Customer feedback: after 3 heating season operation, the indoor heating temperature reached the design requirements of 22 degrees or more. Our heating needs are perfectly solved. Using induction heating furnace units is not only environmentally friendly, but we also save the boiler maintenance and other costs, and save more than 100,000 yuan in annual heating costs.

Project: Hot water supply and space heating for Hohhot High Security Prison
Project Address: Hohhot, Inner Mongolia
Temperature: -20℃
Project overview: Heating hot water for the prison with an area of about 112,000 square meters.
Products used: 17 sets of 240KW Biyuanda high-quality induction heating furnace air units
Operation: The water supply temperature reaches 75℃, guaranteeing safe and reliable heating during the heating season.