Low Pressure and Temperature Test Chamber
Application
The high/low temperature low pressure test chamber is often used for military uses. Sometimes, the low pressure chamber simulates the high mountain environment for testing vehicles, computers, electronic components and packaging materials that need air transport.
Model | KU-504-40 | KU-1000-40 | KU-504-70 | KU-1000-70 | |
Volume | 504L | 1000L | 504L | 1000L | |
Internal size (D×W×H)mm | 800×700×900 | 1000×1000×1000 | 800×700×900 | 1000×1000×1000 | |
Temperature range | -40°C to +150°C | -70°C to +150°C | |||
Temperature fluctuation | ±1.5°C | ||||
Temperature deviation | When temperature ≥ 100℃, ±3.0℃ (atmospheric pressure, empty run); when temperature < 100℃, ±2.0℃ (atmospheric pressure, empty run) | ||||
Temperature increase/decrease speed | 0.7℃ to 1.0℃/min | ||||
Pressure range | Atmospheric pressure to 1 kpa | ||||
Pressure deviation | When pressure ≥40kpa,±2kpa; when pressure 4kpa-40kpa, ±0.5kpa; when ≤4kpa, ±0.1kpa | ||||
Pressure reduction speed | Atmospheric pressure to 1kpa≤30 min (under room temperature) | ||||
Pressure recovery speed | 10kpa/min (adjustable) | ||||
Materials | Housing | Anti-rust cold-rolled steel plates, plastic coated | |||
Internal surface | SUS304 stainless steel plates | ||||
Pressure bearing | Anti-rust thick steel plates, plastic coated | ||||
Insulation | High-quality glass wool | ||||
Regulator | Refrigerator | Semi-enclosed compressor | |||
Cooling method | Air cooling or water cooling | ||||
Vacuuming method | Rotary vane vacuum pump | ||||
Heater | High-quality nichrome fin heater | ||||
Blower | Magnetic transmission | ||||
Observation window | Film coated, hollow glass | ||||
Temperature sensor | Thermal resistance, thermocouple | ||||
Controller | Touchscreen controller |
Note: Our company has the technological capacity to simultaneously satisfy the temperature requirements and humidity requirements under low pressure.
StandardsGB10590-89 | Specification for Low Temperature/Low Air Pressure Test Chambers |
GB15091-89 | Specification for High Temperature/Low Air Pressure Test Chambers |
GB11159-89 | Specification for Low Air Pressure Test Chambers |
GB/T2423.25-199 | Basic Environmental Testing Procedures for Electric and Electronic Products--Test Z/AM: Combined Cold/Low Air Pressure Tests |
GB/T2423.26-1992 | Basic Environmental Testing Procedures for Electric and Electronic Products--Test Z/BM: Combined Dry Heat /Low Air Pressure Tests |
GJB150.2-86 | Environmental Test Methods For Military Equipment--Low Pressure(Altitude) Test |
Optional Configurations
1. Rotary dehumidifier/ polymeric membrane, with a lowest temperature/ humidity content of 5℃/5 %RH.
2. Built-in tempered glass door, easy to move
3. Water purification system, with automatic replenishment function
4. Recorder, save and print testing data
5. Ultrasonic humidifier/ high-pressure spray humidifier, providing continuous high humidity under extreme temperature
6. Dry air blow system, anti-condensation
7. Remote monitoring function, cellphone and computer supportive
Cooling Equipment