DTSD342-9 Electric Power Distribution Monitor

DTSD342-9 Electric Power Distribution Monitor
DTSD342-9 Electric Power Distribution Monitor
DTSD342-9 Electric Power Distribution Monitor
DTSD342-9 Electric Power Distribution Monitor
Request a Quote

General introduction:
DTSD342-9 electric power distribution monitor integrates measurement and recording, electric energy metering, teleindication and telecontrol, large screen LCD display and network communication, which can measure voltage, current, power, power factor, frequency and other parameters of the grid. Besides, the monitor possesses the function of 2~50 times harmonic analysis, calculation of a number of electric energy quality parameters as well as measurement of active and reactive electric energy. RS-485 communication interface is configured which supports MODBUS-RTU and DL/T645 dual communication protocol. With switch input and output function, analog transmission output can be configured.

The monitor can be widely used in substation automation, industrial control and industrial automation system, energy management system, residential power monitoring and other occasions.

It complies with the following standards:
1. GB/T17215.301-2007 special requirements of multi-function electric energy meter.
2. GB/T17215.322-2008 static active electric energy meter (class 0.2S and class 0.5S).
3. GB/T17215.323-2008 static reactive electric energy meter (class 2 and class 3).
4. DL/T 614-2007 multifunctional electric energy meter.
5. DL/T 645-2007 communication protocol of multifunctional electric energy meter.
6. Modbus-RTU.

Technical specifications
  • Three-phase four-wire(without PT) connection diagram
  • Three-phase four-wire(with PT) connection diagram
  • Three-phase three-wire connection diagram
Items Technical index
Wiring form three-phase three-wire, three-phase four-wire, single phase
Measurement Voltage Reference voltage Un:AC380V, AC220V, AC100V, AC57.7V
Measurement range:10V~1.3Un
Power consumption:< 0.05VA(single phase)
Accuracy: RMS 0.2 %
Resolution: 0.01V
Current Rated current In:0.3A, 1A, 1.5A, 5A
Measurement range:0.001In~10A
Power consumption:< 0.05VA(single line rated current)
Accuracy: RMS 0.2 %
Resolution: 0.001A
Power
(active / reactive/ apparent)
Accuracy: 0.2%
Resolution: 0.001kW/kVar/kVA
Grid frequency Measurement range:45Hz~65Hz
Accuracy: 0.2%
Resolution: 0.01Hz
Metering Active electric energy Metering accuracy class: 0.5S
Resolution: 0.01kWh
Reactive electric energy Metering accuracy class: class 2
Resolution: 0.01kvarh
digital signal electric energy pulse output 2 channel electric energy(active and reactive) pulse output
optocoupler isolation, 4000VRMS
Switch output
(optional)
2 channel electromagnetic relay output
normally open
Contact rating: AC 250V /3A; DC 30V /3A
Switch input
(optional)
4 channel dry contact input
optocoupler isolation, 4000VRMS
analog signal Transmission (analog) output
(optional)
4 channel analog signal output
current output type (4~20Ma or 0~20Ma or 0~24mA)
voltage output type (0~5Vor 0~10V)
accuracy: 0.5%
Communication RS-485 communication port
(optional)
Interface type: two-line half duplex
communication rate: 600bps~38400bps
Protocol: Modbus-RTU and DL/T-645
Environment Working temperature -25℃~+60℃
Limit working temperature -35℃~+70℃
Relative humidity ≤95%(RH)
Others Power supply AC or DC power supply
maximum input range: 40V~420V
Power consumption: ≤1W, 2VA
size Outline size(mm):96×96×95 
Hole size(mm):92×92
Weight About 450g

Main functions
DTSD342-9 series products contain a total of 13 models. For specific information, please refer to the following product model and function check table.

Model/Function 9V 9A 9B 9H 9G 9P 9Q 9C 9M 9W 9E 9N 9X
Voltage measurement







Current measurement







Frequency measurement








Active power measurement







Reactive power measurement







Power factor measurement







Apparent power measurement








Active electric energy measurement








Reactive electric energy measurement









Active electricity pulse output port








Reactive electricity pulse output port









Off-limit alarm

Harmonic measurement and analysis











Transmission output

Switch input(teleindication)
Switch output (telecontrol)
RS-485communicaiton

Note: "√" indicates that the function is possessed, and "△" indicates the function is optional.

Main features
1. Our product adopts high-precision sampling and measuring unit together with high-speed MCU data processing unit, which can realize high precision, wide range and accurate measurement as well as fast data analysis.
2. Wide viewing angle LCD display is used to show richer contents.
3. LCD display is equipped with white backlight to meet the requirement of consulting data in dark environment.
4. nonvolatile memory is adopted to store all kinds of data, which can save data for a long time without losing data due to power failure.
5. Support RS-485 communication port and industrial standard communication protocol, convenient and flexible for network construction.

Different communication modules are availabe to satisfy different interface requirements of various users.

WILLFAR as a reliable electric power distribution monitor manufacturer, mainly manufacture meter data management instrument, like electrical power data logger, data concentrator, data collector, and power monitor for smart meter system. To serve daily life much better, WILLFAR company also provides custom meter data management and electrical energy efficiency management solutions in customer needs.