Residential Reverse Osmosis(RO) Membrane

Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Residential Reverse Osmosis(RO) Membrane
Request a Quote

Independently developed by VONTRON, the residential RO element is designed for treatment of raw water containing oxidant substances and high microbe contaminations. Working under an extremely low pressure, this reverse osmosis membrane element is applicable to water purifying devices for residences, hospitals and laboratories.

Residential RO Membrane Element

Model: ULP2008-50P
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1609-50P
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1609-50F
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1809-50Q
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1809-50P
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1809-100Q
Rejection(%): 94
Average Permeate GPD (m³/d): 100 (0.38)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2309-100P
Rejection(%): 97
Average Permeate GPD (m³/d): 100 (0.38)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 30

Model: ULP2809-200
Rejection(%): 95
Average Permeate GPD (m³/d): 200 (0.76)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 25

Model: ULP1810-50
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1810-50Q
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1810-50P
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1810-70
Rejection(%): 91
Average Permeate GPD (m³/d): 70 (0.27)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2010-80
Rejection(%): 94
Average Permeate GPD (m³/d): 80 (0.3)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2010-100Q
Rejection(%): 93
Average Permeate GPD (m³/d): 100 (0.38)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1812-50
Rejection(%): 97.5
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: XLP2012-50
Rejection(%): 96.5
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 30 (0.21)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: HOR2012-50
Rejection(%): 97
Average Permeate GPD (m³/d): 50 (0.19)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP1812-75
Rejection(%): 97.5
Average Permeate GPD (m³/d): 75 (0.28)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2012-100
Rejection(%): 94
Average Permeate GPD (m³/d): 100 (0.38)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2012-125
Rejection(%): 94
Average Permeate GPD (m³/d): 125 (0.48)
Testing Conditions
Pressure psi (MPa): 60 (0.41)
Concentration NaCl (ppm): 250
Recovery (%): 15

Model: ULP2812-200
Rejection(%): 97
Average Permeate GPD (m³/d): 200 (0.76)
Testing Conditions
Pressure psi (MPa): 100 (0.69)
Concentration NaCl (ppm): 500
Recovery (%): 15

Model: ULP3012-300
Rejection(%): 97
Average Permeate GPD (m³/d): 300 (1.14)
Testing Conditions
Pressure psi (MPa): 100 (0.69)
Concentration NaCl (ppm): 500
Recovery (%): 15

Model: ULP3012-400
Rejection(%): 95
Average Permeate GPD (m³/d): 400 (1.52)
Testing Conditions
Pressure psi (MPa): 100 (0.69)
Concentration NaCl (ppm): 500
Recovery (%): 15

Model: ULP3013-400
Rejection(%): 95
Average Permeate GPD (m³/d): 400 (1.52)
Testing Conditions
Pressure psi (MPa): 100 (0.69)
Concentration NaCl (ppm): 500
Recovery (%): 15

Model: ULP3020-420
Rejection(%): 97
Average Permeate GPD (m³/d): 420 (1.6)
Testing Conditions
Pressure psi (MPa): 100 (0.69)
Concentration NaCl (ppm): 500
Recovery (%): 40

Related products
Send Message
Inquiry
Inquiry