JGGP(JGP) 6.6KV Silicone Insulated Motor Connection Wire

JGGP(JGP) 6.6KV Silicone Insulated Motor Connection Wire
Request a Quote

Construction
Conductor: Bare copper, tinned copper
Insulator: Silicone rubber
Jacket: Synthetic yarn braiding with silicone resin coating
Rated temp: -60℃-180℃
Rated volt: 6600V
Test Voltage: 14.8KV. 1Min
Flame test: FT 2

Application
Thanks to the above characters, JGGP(JGP) 6.6KV silicone insulated motor connection wires are used where high flexibility is required and in high temperature conditions. It is therefore a suitable connection cable for home electric appliance, high voltage machines like transformers, generators, motors, traction machines.

Technical Parameters
Size Conductor Insulation thickness Braiding thickness Wire OD Resistance
Composition OD Nominal OD Nominal Toler. Ω/KM
mm² No./mm mm mm mm mm mm mm Max.
4.0 56/0.30 2.70 2.6 7.90 0.25 8.4 ±0.30 5.09
6.0 84/0.30 3.30 2.6 8.50 0.25 9.0 ±0.40 3.39
10.0 84/0.40 4.60 2.6 9.80 0.25 10.3 ±0.40 1.95
16.0 126/0.40 5.80 2.6 11.0 0.25 11.5 ±0.40 1.24
25.0 196/0.40 7.30 2.8 12.9 0.30 13.5 ±0.40 0.795
35.0 276/0.40 8.60 2.8 14.2 0.30 14.8 ±0.50 0.565
50.0 396/0.40 10.5 3.0 16.5 0.30 17.1 ±0.50 0.393
70.0 360/0.50 12.40 3.0 18.4 0.30 19.0 ±0.50 0.277
95.0 475/0.50 14.50 3.2 20.9 0.35 21.6 ±0.50 0.210
120.0 608/0.50 16.0 3.2 22.4 0.35 23.1 ±0.50 0.164
150.0 756/0.50 18.0 3.4 24.8 0.35 25.5 ±0.60 0.132
185.0 925/0.50 20.0 3.4 26.8 0.35 27.5 ±0.60 0.108
240.0 1221/0.50 23.0 3.6 30.2 0.40 31.0 ±0.80 0.0817
300.0 1517/0.50 26.0 3.8 33.6 0.40 34.4 ±0.80 0.0654

Mechanical Properties
Tensile strength: ≥5N/mm²
Elongation at break of insulation: ≥250%
Min. Bending radius: 7×OD
Standard: UL758, UL62, UL1581

Characteristics
JGGP(JGP) 6.6KV silicone insulated motor connection wire has very good flexibility and good performance of resistance to high temperature, ranging from -55℃ up to 180℃.
The use of silicone rubber, a high grade corona resistant insulation material, gives the cable excellent dielectric strength.
The braided synthetic yarn covering which is applied directly to the insulation, gives the cable, because of its short braiding pitch and high compactness, an excellent mechanical protection by maintaining good flexibility.
The varnishing of the braiding results in good antifriction properties, high abrasion resistance and excellent chemical resistance against transformer oil, light fuel oil and most types of cleaning agents.
In the event of fire, no corrosive and toxic gases will be given off.
Hence, damage caused by fire can be kept to minimum.

Form