KYN61-40.5 Removable AC Metal-clad Switchgear
Rated voltage (kV) 40.5
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1250, 1600, 2000, 2500
4s Rated short-time withstand current (kA) 25, 31.5
Rated peak withstand current (kA) 63, 80
KYH1-40.5 Removable AC Metal-clad Switchgear
Rated voltage (kV) 40.5
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1250, 1600, 2000, 2500
4s Rated short-time withstand current (kA) 25, 31.5
Rated peak withstand current (kA) 63, 80
KYH1-27.5 Removable AC Railway Metal-clad Switchgear
Rated voltage (kV) 27.5
Rated frequency (Hz) 50
Rated current (A) 1600
Rated short-time withstand current (kA) 31.5
Rated peak withstand current (kA) 80
KYH1-24 Removable AC Metal-clad Switchgear
Rated voltage (kV) 24
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1250, 1600, 2000, 2500
4s Rated short-time withstand current (kA) 25, 31.5
Rated peak withstand current (kA) 63, 80
KYN28--12 Removable AC Metal-clad Switchgear
Rated voltage (kV) 12
Rated frequency (Hz) 50, 60
Rated current (A) 630~4000
4s Rated short-time withstand current (kA) 16, 20, 25, 31.5, 40, 40.5
Rated peak withstand current (kA) 40, 50, 63, 80, 100, 125
KYH3-12S Removable AC Double-Busbar Metal-clad Switchgear
Rated voltage (kV) 12
Rated frequency (Hz) 50
Rated current (A) 1250
4s Rated short-time withstand current (kA) 31.5
Rated peak withstand current (kA) 80
KYN28C-12 Removable AC Metal-clad Switchgear
Rated voltage (kV) 7.2, 12
Rated frequency (Hz) 50, 60
Rated current (A) Fuse: 315
Main busbar: 630~4000
4s Rated short-time withstand current (kA) 40
Rated peak withstand current (kA) 100
KYN96-12(AMS) Removable AC Metal-clad Switchgear
Rated voltage (kV) 12
Rated frequency (Hz) 50
Rated current (A) Main busbar: 630, 1250/1600, 2000/2500, 3150
Branch busbar: 630, 1250, 1600, 2000, 2500, 3150
4s Thermal-stable current (kA) 20, 25, 31.5, 40
Rated dynamic-stable current (peak) (kA) 50, 63, 80, 100
KYN18-12 Removable AC Metal-clad Switchgear
Rated voltage (kV) 12
Rated current (A) 630, 1250, 1600, 2000, 3150
Rated short circuit breaking current(kA) 25, 31.5, 40
4s Rated short-time withstand current (kA) 25, 31.5, 40
Rated peak withstand current (kA) 63, 80, 100
Mvnex-12 Removable AC Metal-clad Switchgear
Rated voltage (kV) 12
Rated frequency (Hz) 50
Rated current (A) CB: 630, 1250, 2500, 3150
Busbar: 630, 1250, 2500, 3150
4s Rated thermal stability withstand current (kA) 25, 31.5, 40
Rated peak withstand current (kA) 63, 80, 100