Technical Data
15-15-100 Hot Oil PumpsModel | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
15-15-100 | 3 | 10 | 2800 | 0.45 | 0.75 | 20 | 801 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
15-15-100 | 3 | 10 | 2800 | 0.45 | 0.75 | 20 | 801 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
15-15-100B | 1 | 10 | 2800 | 0.2 | 0.37 | 15 | A02-7112 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
20-20-100 | 1 | 10 | 2800 | 0.09 | 0.37 | 26 | A02-7112 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
20-20-125 | 1.5 | 22 | 2800 | 0.22 | 0.75 | 30 | 801 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
40-25-160 | 10 | 28 | 2900 | 1.72 | 2.2 | 45 | 90L |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
25-25-160 | 3 | 27 | 2900 | 0.53 | 1.5 | 30 | 90S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
32-32-160 | 6 | 28 | 2900 | 0.85 | 1.5 | 50 | 90S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
50-32-160 | 12.5 | 30 | 2900 | 1.9 | 3 | 57 | 100L |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
50-32-200 | 18 | 40 | 2900 | 3.92 | 5.5 | 50 | 132SI |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
50-32-200A | 16 | 32 | 2900 | 3.35 | 4 | 42 | 112M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
50-32-250 | 12.5 | 80 | 2900 | 6.2 | 11 | 44 | 160MI |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-50-160 | 20 | 32 | 2900 | 3.17 | 5.5 | 55 | 132S1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-200 | 30 | 48 | 2900 | 6.3 | 7.5 | 62 | 132S2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-200A | 25 | 35 | 2900 | 4 | 5.5 | 59 | 132S1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-250 | 25 | 80 | 2900 | 10.3 | 15 | 53 | 160M2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-250A | 20 | 51 | 2900 | 5.67 | 7.5 | 49 | 132S2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-315 | 25 | 125 | 2900 | 18.9 | 30 | 45 | 200L1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
65-40-315A | 22.5 | 100 | 2900 | 15.3 | 22 | 40 | 180M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-200 | 50 | 50 | 2900 | 9.7 | 15 | 70 | 160M2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-200A | 45 | 40 | 2900 | 7.8 | 11 | 63 | 160M1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-200B | 40 | 32 | 2900 | 6.37 | 7.5 | 55 | 132S2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-250 | 50 | 80 | 2900 | 17.1 | 22 | 58 | 180M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-250A | 43 | 60 | 2900 | 12.8 | 15 | 55 | 160M2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-315 | 50 | 125 | 2900 | 30.4 | 45 | 56 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
80-50-3I5A | 45 | 100 | 2900 | 23.6 | 30 | 52 | 200L1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-200 | 100 | 50 | 2900 | 18.4 | 22 | 74 | 180M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-200A | 94 | 44 | 2900 | 16 | 22 | 70 | 180M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-200B | 87 | 38 | 2900 | 13.8 | 15 | 65 | 160M2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-200C | 80 | 32 | 2900 | 11.8 | 15 | 59 | 160M2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-250 | 100 | 80 | 2900 | 32.06 | 37 | 68 | 200L2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-250A | 95 | 72 | 2900 | 29 | 37 | 64 | 200L2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-250B | 90 | 65 | 2900 | 26.2 | 30 | 61 | 200L1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-250C | 85 | 50 | 2900 | 20.3 | 30 | 57 | 200L1 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-315 | 100 | 125 | 2900 | 50.06 | 75 | 68 | 280S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-315A | 95 | 113 | 2900 | 45.23 | 55 | 64.63 | 250M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-315B | 90 | 100 | 2900 | 40.5 | 55 | 60.5 | 250M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
100-65-315C | 82 | 84 | 2900 | 34.76 | 45 | 54 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-200 | 200 | 50 | 2900 | 35.4 | 45 | 77 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-200A | 178 | 40 | 2900 | 26.6 | 37 | 73 | 200L2 |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-250 | 200 | 70 | 2900 | 47 | 55 | 80 | 250M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-250A | 190 | 63 | 2900 | 41.6 | 55 | 78 | 250M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-250B | 180 | 57 | 2900 | 37.9 | 45 | 74 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-250C | 170 | 51 | 2900 | 32.15 | 45 | 72 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
125-100-250D | 150 | 70 | 2900 | 40 | 45 | 70 | 225M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
150-150-200 | 350 | 50 | 2900 | 60 | 75 | 80 | 280S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
150-150-200A | 313 | 40 | 2900 | 45 | 55 | 76 | 250M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
200-150-400 | 350 | 50 | 1450 | 61.8 | 75 | 78 | 280S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
200-150-400A | 330 | 45 | 1450 | 52.8 | 75 | 77 | 280S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
250-200-400 | 500 | 50 | 1480 | 86.2 | 110 | 79 | 315S |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
250-200-500 | 500 | 80 | 1480 | 136 | 160 | 76.5 | 315M |
Model | Volume Flow Rate (Q) m3/h | Head m | Shaft rotation speed (n) r/min | Power Kw | Volumetric efficiency (η) % | Motor (Y) Type Motor No. | |
Fuel Power | Motor Power | ||||||
250-200-500A | 400 | 50 | 1480 | 75 | 90 | 73 | 280M |
Features:
Both use packing seal and mechanical seal to seal the shaft ends guarantee the seals, high resisting material used in the packing seal and abrasive resisting metal alloy used in the mechanical seal make sure of the seals, packing seal use the Teflon(PTFE)as seal strip to improve the seal reliability ,the alloys used as HT200;II.ZG230-450;III.1Cr18Ni9Ti,OCr18Ni12-Mo.
These hot oil pump are cooled by water, water cooled hot oil pumps