Outdoor Disconnect Switch

Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Outdoor Disconnect Switch
Request a Quote
GW49-252 Outdoor HV Disconnect Switch
Rated voltage (kV) 252
Rated frequency (Hz) 50
Rated current (A) 2000, 2500, 3150, 4000
Rated short-time withstand current (with earth switch) (kA) 40, 50, 63
Rated peak withstand current (with earth switch)(kA) 100, 125, 160
GW48-252 Outdoor HV Disconnect Switch
Rated voltage (kV) 252
Rated frequency (Hz) 50
Rated current (A) 2000, 2500, 3150, 4000
Rated short-time withstand current (with earth switch) (kA) 40, 50, 63
Rated peak withstand current (with earth switch)(kA) 100, 125, 160
GW7-252 Outdoor HV Disconnect Switch
Rated voltage (kV) 252
Rated current (A) 2000, 2500, 3150, 4000
Rated short-time withstand current (with earth switch) (kA) 50, 63
Rated short-time withstand time (s) 3
Rated peak withstand current (kA) 125, 160
JW6-252 Outdoor High Voltage Earthing Switch
Rated voltage (kV) 252
Rated short-time withstand current (kA) 63
Rated short-time withstand current (peak) (kA) 160
1 min power frequency withstand voltage (effective kV) 460
Lightning impulse withstand voltage (peak) (kV) 1050
GW4 Series Outdoor AC HV Disconnect Switch
Rated voltage (kV) 72.5, 126, 145
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1250, 1600, 2000
4s Rated short-time withstand current (kA) 25, 31.5, 40
Rated peak withstand current (kA) 63, 80, 100
GW5 Series Outdoor AC Disconnect Switch
Rated voltage (kV) 40.5, 72.5, 126, 145
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1250, 1600, 2000
4s Rated short-time withstand current (kA) 25, 31.5, 40
Rated peak withstand current (kA) 63, 80, 100
GWHY1-27.5 Outdoor MV Disconnect Switch
Rated voltage (kV) 27.5
Rated current (A) 630, 1250, 1600
Rated short-time withstand current (kA) 20, 31.5
Rated peak withstand current (kA) 50, 80
Rated lightning impulse withstand voltage(kV) To earth:185 across open contacts:215
GW4-12/40.5 Outdoor MV Disconnect Switch
Rated voltage (kV) 12, 40.5
Rated current (A) 200, 400, 630, 1000, 1250
4s Rated short-time withstand current (kA) 16, 20, 25, 31.5
Rated withstand current (kA) 40, 50, 63, 80
GW-12/24/40.5 Outdoor HV Disconnect Switch
Rated voltage (kV) 12, 24, 40.5
Rated frequency (Hz) 50, 60
Rated current (A) 630, 1000, 1250
4s Rated short-time withstand current (kA) 20, 25
Rated peak withstand current (kA) 50, 63
GWR-12/24/40.5 Outdoor MV Disconnect Switch
Rated voltage (kV) 12, 24, 40.5
Rated frequency (Hz) 50, 60
Rated current (A) 100
Maximum breaking current (kA) 5
Main circuit resistance (μΩ) ≤150
GW9-12/24/40.5 Outdoor MV Disconnect Switch
Rated voltage (kV) 12, 24, 36
Rated frequency (Hz) 50, 60
Rated current (A) 630
Rated short-time withstand current (kA) 20, 25
Rated peak withstand current (kA) 31.5, 50
GW1-12 HV Disconnect Switch
Rated voltage (kV) 12
Rated frequency (Hz) 50, 60
Rated current (A) 400, 630, 800, 1000, 1250
4s Rated short-time withstand current (kA) 20, 25, 40
Rated peak withstand current (kA) 50, 63, 100
GW13-40.5 MV Neutral Earthing Switch
Rated voltage (kV) 40.5, 72.5, 126,
Rated frequency (Hz) 50
Rated current (A) 630
4s Thermal stability current (kV) 20
Dynamic current (peak) (kA) 50
Form
Related products
Send Message
Inquiry
Inquiry