As a trustworthy thermocouple supplier, we can also provide various thermocouple accessories. You can see the detailed information about our PTFE insulated KX thermocouple extension wire 2×7/0.2mm.

Thermocouple Extension Wire
1. Conductors
Positive: chromel
Negative: alumel
2. Insulation: extruded PTFE
3. Overall sheath: SSB

PTFE Insulated KX Thermocouple Extension Wire 2×7/0.2mm
1.Subject
This specification covers the requirements for PTFE insulated and PTFE sheathed thermocouple extension cable (KX type with metallic braided sheath, 2×7/0.2mm).

2. Technical Feature
A. Conductor
Stranded thermocouple extension wire
Conductor Size (AWG) Quantity of strands and gauge
24mm 7/32, 0.20mm

B. Insulation
Extruded PTFE (260℃)
Nominal insulation thickness: 0.31±0.2mm
Color code
Positive: yellow
Negative: red

C. Assembly
The two conductors (positive and negative) in the KX thermocouple extension wire are parallel.

D. Overall sheath
Extruded PTFE (260℃)
Nominal insulation thickness: 0.38±0.2mm
Color code: yellow

E. Metal braided sheath
Stainless steel round wire braided with blue tracer (85% minimum coverage)

3. Dimensions and Tolerance of the PTFE Insulated KX Thermocouple Extension Wire
Dimensions/tolerances (mm): (1.6±0.25)×(2.5±0.25)

4. Calibration Tolerance
Temperature range Standard tolerance* Special tolerance*
0℃ to 200℃ ±2.2℃ or 0.75% ±1.1℃ or 0.4%

* whichever is greater

Thermocouple type available: KX, JX, TX, EX, NX, RX,SX, and some other compensating cables like KCA, KCB, and so on.

Packing and delivery
    Related products