JQX-53FF/RH1B/RY2SS Series General Purpose Relay
Request a Quote
Features
- Switching current of the contact reaches up to 10A
- Electrical life is at least 100,000 operations
- Two and three sets of Form C contacts
- Optional sockets
- Built-in LED, test button
Contact parameters
Contact ratings | 1Z | 2Z | 3Z | |
RH1B-U | RY2SS-U | JQX-52FF-2Z | JQX-52FF-3Z | |
Contact resistance | 50mΩ (1A 6VDC) | 50mΩ (1A 6VDC) | 50mΩ (1A 6VDC) | |
Contact capacity | 10A/30VDC 250VAC | 3A/30VDC 250VAC | 10A/30VDC 250VAC | 10A/30VDC 250VAC |
Parameters
Insulation resistance | 500MΩ (500VDC) |
Dielectric strength | BCC≥1500VAC 1min |
BOC≥1000VAC 1min | |
COC≥1500VAC 1min | |
Operating time | 25ms/15ms |
Specifications
Model | Coil | Electrical life | Mechanical life | Operating temperature | Weight | Mounting methods | |
Rated voltage | Rated power | ||||||
JQX-53FF-2Z | DC 6 to 220V AC 6 to 380V | DC≤2W AC≤3.5VA | 105 OPS | 107 OPS | 40℃~70℃ | ≤72g | printed-circuit board, flange, outlet |
JQX-53FF-3Z | DC 6 to 220V AC 6 to 380V | DC≤2W AC≤3.5VA | 105 OPS | 107 OPS | 40℃~70℃ | ≤76g | |
RH1B-U | DC 6 to 220V AC 6 to 380V | DC≤0.9W AC≤1.2VA | 105 OPS | 107 OPS | 40℃~70℃ | ≤22g | |
RY2SS-U | DC 6 to 220V AC 6 to 380V | DC≤1.5W AC≤2.5VA | 105 OPS | 107 OPS | 40℃~70℃ | ≤22g |
Outline dimension, bottom View